Liquid Management

SUCTION LINE
ACCUMULATORS

KNOW WHAT YOU’RE LOOKING FOR?

SUCTION LINE ACCUMULATORS

Low Pressure | MAXIMUM WORKING PRESSURE: 450 PSIG

Features

Suction line accumulators are designed to act as a temporary holding vessel between the outlet of the evaporator and the inlet of the compressor. During flood-back conditions, the accumulator traps the liquid charge and allows it to be evaporated and fed to the compressor at a controlled rate.

  • Nitrogen tested for cleanliness
  • Nickel plated connections and powder-paint finish
  • Screened orifice for proper oil return
  • Integrated 435°F fusible plug on vessels over 3″ in diameter (smaller vessels are exempt)

 

Catalog Number ODS Dimensions Recommended Tons of Refrigeration Holding Capacity
R134A R22 R404A
-40ºF 40ºF -40ºF 40ºF -40ºF 40ºF
A B Min Max Min Max Min Max Min Max Min Max Min Max R410A
Vert. A3-04(HP)* 1/2" 3” 11" 0.01 0.07 0.1 0.58 0.02 0.16 0.15 0.91 0.02 0.14 0.12 0.72 1.50 lbs
A4-04 1/2" 4" 11" 0.01 0.07 0.1 0.58 0.02 0.16 0.15 0.91 0.02 0.14 0.12 0.72 2.75 lbs
A4-05 5/8" 4" 11" 0.01 0.17 0.12 1.28 0.03 0.35 0.19 2.01 0.03 0.31 0.15 1.59 3.00 lbs
A4-06 3/4" 4" 10" 0.02 0.25 0.16 1.92 0.04 0.53 0.25 3.01 0.03 0.47 0.19 2.39 2.50 lbs
A4-06B 3/4" 4" 10.63" 0.02 0.25 0.16 1.92 0.04 0.53 0.25 3.01 0.03 0.47 0.19 2.39 2.75 lbs
A5-07 7/8" 5" 10" 0.04 0.34 0.35 2.55 0.09 0.7 0.55 4 0.08 0.62 0.44 3.17 3.25 lbs
A5-07F 7/8" 5" 13" 0.04 0.34 0.35 2.55 0.09 0.7 0.55 4 0.08 0.62 0.44 3.17 4.75 lbs
A6-11 1 1/8" 6" 18.75" 0.06 0.78 0.51 5.84 0.14 1.61 0.8 9.16 0.12 1.42 0.63 7.26 11.25 lbs
A6-11W 1 1/8" 6" 15" 0.06 0.78 0.51 5.84 0.14 1.61 0.8 9.16 0.12 1.42 0.63 7.26 8.50 lbs
A6-13 1 3/8" 6" 23" 0.17 1.46 1.29 10.9 0.35 3.02 2.02 17.09 0.31 2.66 1.6 13.55 14.00 lbs
A6-13Z 1 3/8" 6" 20.25" 0.17 1.46 1.29 10.9 0.35 3.02 2.02 17.09 0.31 2.66 1.6 13.55 12.00 lbs
A6-15 1 5/8" 6" 23" 0.44 2.42 3.27 18.04 0.9 4.99 5.12 28.27 0.79 4.4 4.06 22.42 13.00 lbs
A6-15R 1 5/8" 6" 24.75" 0.44 2.42 3.27 18.04 0.9 4.99 5.12 28.27 0.79 4.4 4.06 22.42 14.25 lbs
Horz A6-11HZ 1 1/8" 6" 16.5" 0.06 0.78 0.51 5.84 0.14 1.61 0.8 9.16 0.12 1.42 0.63 7.26 10.75 lbs
A6-13HZ 1 3/8" 6" 22.5" 0.17 1.46 1.29 10.9 0.35 3.02 2.02 17.09 0.31 2.66 1.6 13.55 15.00 lbs
A6-15HZB 1 5/8" 6" 30" 0.44 2.42 3.27 18.04 0.9 4.99 5.12 28.27 0.79 4.4 4.06 22.42 20.00 lbs
A6-15HZC 2 1/8" 6" 48" 0.85 5.12 6.34 38.09 1.75 10.55 9.94 59.69 1.55 9.3 7.89 47.34 34.75 lbs

All capacities are calculated for 85%.

*For heat pump models, add “HP” to the end of the catalog number.
(ex: A3-04 becomes A3-04HP)

How to choose

The accumulator should not be sized for less than 50% of the total system charge. The minimum capacity is the lowest amount that will ensure proper oil return.

For refrigerants and conditions not listed, see our online sizing calculator or contact us for assistance.

SUCTION LINE ACCUMULATORS

High Pressure | MAXIMUM WORKING PRESSURE: 675 PSIG

Features

Suction line accumulators are designed to act as a temporary holding vessel between the outlet of the evaporator and the inlet of the compressor. During flood-back conditions, the accumulator traps the liquid charge and allows it to be evaporated and fed to the compressor at a controlled rate.

  • Welded design for higher strength and a powder paint finish
  • Nickel plated connections and powder-paint finish
  • Screened orifice for proper oil return
  • Integrated 435°F fusible plug on UL models over 3″ in diameter (smaller vessels are exempt)

          

Catalog Number ODS Dimensions Recommended Tons of Refrigeration Holding Capacity
R410A
40ºF
A B Min Max R410A
UL Listed AH3-04(HP*) 1/2" 3” 11" 0.22 1.32 1.5 lbs
AH4-04 1/2" 4" 11" 0.22 1.32 2.5 lbs
AH4-05 5/8" 4" 11" 0.28 2.91 3 lbs
AH4-05A 5/8" 4" 6.63" 0.28 2.91 1 lbs
AH4-05B 5/8" 4" 11" 0.28 2.91 3.25 lbs
AH4-06 3/4" 4" 10" 0.36 4.36 2.5 lbs
AH4-06B 3/4" 4" 10.63" 0.36 4.36 3.5 lbs
AH5-07 7/8" 5" 10" 0.8 7.36 3.25 lbs
AH5-07F 7/8" 5" 13" 0.8 7.36 4.75 lbs
AH6-11 1 1/8" 6" 18.75" 1.16 14.73 12 lbs
AH6-11AE 1 1/8" 6" 15" 1.16 14.73 8.25 lbs
AH6-13 1 3/8" 6" 23" 2.93 24.74 13.5 lbs
AH6-13Z 1 3/8" 6" 20.25" 2.93 24.74 11.5 lbs
AH6-15 1 5/8" 6" 23" 7.42 40.93 13 lbs
AH6-15R 1 5/8" 6" 24.75" 7.42 40.93 13.5 lbs
ASME AH8-15 1 5/8" 8.625" 22" 7.42 40.93 24 lbs
AH8-21 2 1/8" 8.625" 22" 14.4 98.54 24 lbs
AH10-21 2 1/8" 10.75" 22" 14.4 98.54 33.75 lbs
AH10-25 2 5/8" 10.75" 22" 20.46 140.23 29.5 lbs
AH10-31 3 1/8" 10.75" 25" 28.8 208.45 25.25 lbs
AH12-31 3 1/8" 12.75" 25" 28.8 208.45 52 lbs
Catalog Number ODS Dimensions Recommended Tons of Refrigeration Holding Capacity
R410A
40ºF
A B Min Max R410A
UL Listed AH3-04(HP*) 1/2" 3” 11" 0.22 1.32 1.5 lbs
AH4-04 1/2" 4" 11" 0.22 1.32 2.5 lbs
AH4-05 5/8" 4" 11" 0.28 2.91 3 lbs
AH4-05A 5/8" 4" 6.63" 0.28 2.91 1 lbs
AH4-05B 5/8" 4" 11" 0.28 2.91 3.25 lbs
AH4-06 3/4" 4" 10" 0.36 4.36 2.5 lbs
AH4-06B 3/4" 4" 10.63" 0.36 4.36 3.5 lbs
AH5-07 7/8" 5" 10" 0.8 7.36 3.25 lbs
AH5-07F 7/8" 5" 13" 0.8 7.36 4.75 lbs
AH6-11 1 1/8" 6" 18.75" 1.16 14.73 12 lbs
AH6-11AE 1 1/8" 6" 15" 1.16 14.73 8.25 lbs
AH6-13 1 3/8" 6" 23" 2.93 24.74 13.5 lbs
AH6-13Z 1 3/8" 6" 20.25" 2.93 24.74 11.5 lbs
AH6-15 1 5/8" 6" 23" 7.42 40.93 13 lbs
AH6-15R 1 5/8" 6" 24.75" 7.42 40.93 13.5 lbs
ASME AH8-15 1 5/8" 8.625" 22" 7.42 40.93 24 lbs
AH8-21 2 1/8" 8.625" 22" 14.4 98.54 24 lbs
AH10-21 2 1/8" 10.75" 22" 14.4 98.54 33.75 lbs
AH10-25 2 5/8" 10.75" 22" 20.46 140.23 29.5 lbs
AH10-31 3 1/8" 10.75" 25" 28.8 208.45 25.25 lbs
AH12-31 3 1/8" 12.75" 25" 28.8 208.45 52 lbs

All capacities are calculated for 85%.

*For heat pump models, add “HP” to the end of the catalog number.
(ex: AH3-04 becomes AH3-04HP)

How to choose

The accumulator should not be sized for less than 50% of the total system charge. The minimum capacity is the lowest amount that will ensure proper oil return.

For refrigerants and conditions not listed, see our online sizing calculator or contact us for assistance.

ASME ACCUMULATORS

MAXIMUM WORKING PRESSURE: 450 PSIG

Features

ASME accumulators are used to prevent costly damage of the compressor from liquid slugging during a flood-back condition. Our accumulators capture excess liquid leaving the evaporator, allowing the system to vaporize it during normal operation, returning only refrigerant vapor to the compressor. A weep hole is included on the internal tube to facilitate proper oil return from the accumulator to the operating system.

  • Low pressure drop
  • Positive oil return
  • Powder paint finish to protect the accumulator during condensation

   

How To Choose

The accumulator is placed between the evaporator and compressor to intercept excess liquid. To size the accumulator, select the model with the tonnage nearest to the tonnage of the operating system.

Care must be taken to evaluate the amount of liquid holding capacity needed. We recommend the holding capacity not be less than 50% of the system charge. The minimum tonnage is the lowest capacity that will provide adequate oil return from the accumulator.

While these are general guidelines, it is the responsibility of the system designer to select and apply the accumulator properly.

Contact us for help in selecting the proper model.

Catalog Number Dimensions ODS Holding Capacity Recommended Tons of R22 Recommended Tons of R404A
-40°F -20°F 0°F 20°F 40°F -40°F -20°F 0°F 20°F 40°F
A B R404A Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max
Vert. A8-15 8.625" 22" 1 5/8" 26 lbs 0.9 4.9 1.4 8.1 2.3 12.8 3.5 19.3 5.1 28.2 0.7 4.4 1.3 7.4 2.1 12.1 3.4 18.8 5.1 28.3
A8-21 8.625" 22" 2 1/8" 26 lbs 1.7 10.5 2.8 17.2 4.5 27 6.8 40.8 9.9 59.6 1.5 9.3 2.6 15.7 4.2 25.5 6.6 39.7 9.9 59.8
A10-21 10.75" 22" 2 1/8" 38 lbs 1.7 10.5 2.8 17.2 4.5 27 6.8 40.8 9.9 59.6 1.5 9.3 2.6 15.7 4.2 25.5 6.6 39.7 9.9 59.8
A10-25 10.75" 22" 2 5/8" 38 lbs 2.4 16 4 26.2 6.4 41 9.6 62 14.1 90.5 2.2 14.1 3.7 23.9 6 38.7 9.4 60.2 14.1 90.7
A10-31 10.75" 25" 3 1/8" 30 lbs 3.5 23.4 5.7 38.3 9 60.1 13.6 90.6 19.8 132.4 3.1 20.6 5.2 35 8.5 56.6 13.2 88.1 19.9 132.7
A12-31 12.75" 25" 3 1/8" 55 lbs 3.5 23.4 5.7 38.3 9 60.1 13.6 90.6 19.8 132.4 3.1 20.6 5.2 35 8.5 56.6 13.2 88.1 19.9 132.7
A14-41 14" 34" 4 1/8" 87 lbs 12 37.2 19.7 61 30.8 95.7 46.5 144.4 68 211 10.6 32.9 17.9 55.7 29.1 90.3 45.2 140.3 68.2 211.4
A16-41 16" 31" 4 1/8" 92 lbs 12 37.2 19.7 61 30.8 95.7 46.5 144.4 68 211 10.6 32.9 17.9 55.7 29.1 90.3 45.2 140.3 68.2 211.4
A20-41 20" 45" 4 1/8" 248 lbs 12 37.2 19.7 61 30.8 95.7 46.5 144.4 68 211 10.6 32.9 17.9 55.7 29.1 90.3 45.2 140.3 68.2 211.4
Horz. A8-25HZA 8.625" 24" 2 5/8" 32 lbs 1.7 10.5 2.8 17.2 4.5 27 6.8 40.8 9.9 59.6 1.5 9.3 2.6 15.7 4.2 25.5 6.6 39.7 9.9 59.8
A10-31HZA 10.75" 24" 3 1/8" 46 lbs 3.5 23.4 5.7 38.3 9 60.1 13.6 90.6 19.8 132.4 3.1 20.6 5.2 35 8.5 56.6 13.2 88.1 19.9 132.7

All capacities are calculated for 85%.

*Custom sizes are also available

HEAT EXCHANGE ACCUMULATORS

Vertical | MAXIMUM WORKING PRESSURE: 450 PSIG

Features

Heat exchange accumulators provide an internal coil or loop to provide heat transfer. Discharge gas or liquid refrigerant can be used in the coil/loop. The coil/loop does not have a rated capacity. Therefore, field testing will need to be considered for your application if relying on certain performance conditions.

All other characteristics are the same as non-heat exchange models. UL models include an integrated fusible plug rated to 430°F.

   

Catalog Number Dimensions ODS Coil Conn. Holding Capacity Recommended Tons of R22 Recommended Tons of R404A
-40°F -20°F 0°F 20°F 40°F -40°F -20°F 0°F 20°F 40°F
A B R404A Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max
UL A6-11HE 6" 15" 1 1/8" 5/8" 9.00 lbs 0.1 1.6 0.2 2.6 0.3 4.1 0.5 6.2 0.8 9.1 0.1 1.4 0.2 2.4 0.3 3.9 0.5 6 0.8 9.1
A6-13HE 6" 23" 1 3/8" 5/8" 12.75 lbs 0.3 3 0.5 4.9 0.9 7.7 1.3 11.6 2 17 0.3 2.6 0.5 4.5 0.8 7.3 1.3 11.3 2 17.1
A6-15HE 6" 23" 1 5/8" 5/8" 11.25 lbs 0.9 4.9 1.4 8.1 2.3 12.8 3.5 19.3 5.1 28.2 0.7 4.4 1.3 7.4 2.1 12.1 3.4 18.8 5.1 28.3
ASME A8-21HE 8.625" 19.75" 2 1/8" 7/8" 17.00 lbs 1.7 10.5 2.8 17.2 4.5 27 6.8 40.8 9.9 59.6 1.5 9.3 2.6 15.7 4.2 25.5 6.6 39.7 9.9 59.8
A10-25HE 10.75" 21.5" 2 5/8" 1 1/8" 29.50 lbs 2.4 16 4 26.2 6.4 41 9.6 62 14.1 90.5 2.2 14.1 3.7 23.9 6 38.7 9.4 60.2 14.1 90.7
A10-31HE 10.75" 21.5" 3 1/8" 1 1/8" 28.75 lbs 3.5 23.4 5.7 38.3 9 60.1 13.6 90.6 19.8 132.4 3.1 20.6 5.2 35 8.5 56.6 13.2 88.1 19.9 132.7

All capacities are calculated for 85%.

Heat Exchange Accumulators

Horizontal | MAXIMUM WORKING PRESSURE: 450 PSIG

Features

Heat exchange accumulators provide an internal coil or loop to provide heat transfer. Discharge gas or liquid refrigerant can be used in the coil/loop. The coil/loop does not have a rated capacity. Therefore, field testing will need to be considered for your application if relying on certain performance conditions.

All other characteristics are the same as non-heat exchange models. UL models include an integrated fusible plug rated to 362°F.

   

Catalog Number Dimensions ODS Coil Conn. Holding Capacity Recommended Tons of R22 Recommended Tons of R404A
-40°F -20°F 0°F 20°F 40°F -40°F -20°F 0°F 20°F 40°F
A B R404A Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max
UL A6-13HEZ 6" 22.5" 1 3/8" 5/8" 17.00 lbs 0.4 1.8 0.23 2.9 0.36 4.5 0.54 6.8 0.8 9 0.4 1.4 0.2 2.6 0.33 4 0.5 6.5 0.8 9
A6-15HEZ 6" 30" 1 5/8" 3/4" 23.00 lbs 0.5 2.8 0.57 4.8 0.9 7.6 1.4 11 3 15.4 0.5 2.7 0.5 4.3 0.83 7 1.3 11 3.2 16.5
A6-15HEZC 6" 48" 2 1/8" 7/8" 34.00 lbs 2 12 4 18 5 27 7 41 10 60 2 10 3 17 5 28 8 42 12 65
ASME A8-25HEZA 8.625" 24" 2 5/8" 1 3/8" 18.00 lbs 4 17 6 27 8 41 10 62 14 90 4 17 6 27 8 41 10 62 14 90
A10-31HEZ 10.75" 24" 3 1/8" 1 3/8" 42.00 lbs 6 25 9 40 12 61 15 92 20 132 5 22 8 38 12 61 19 94 29 143

All capacities are calculated for 85%.